Description
Post Occupancy Evaluation plus Measurements (POE+M) has revealed that thermal, visual, acoustic and even air quality standards derived through controlled experimentation alone does not ensure comfort or health in buildings. Introducing human input into environmental standards and into user centric controls is critically needed for a sustainable future. For over a decade, CMU’s Center for Building Performance & Diagnostics has been gathering POE+M data from over 1500 workstations around the world and testing the benefits on innovative environmental control systems. The separation of ambient and task conditioning, the provision of task controls, the introduction of occupant voting and bio-signal inputs into ambient and task set-points, offers major gains in comfort, task performance, energy savings, as well as health and wellness.
Recommended Citation
Loftness, Vivian; Aziz, Azizan; Hartkopf, Volker; Lam, Khee Poh; and Lasternas, Bertrand, "Humans and Nature in the Loop: Integrating occupants & natural conditioning into advanced controls for high performance buildings" (2018). International Building Physics Conference 2018. 4.
DOI
https://doi.org/10.14305/ibpc.2018.k03
Creative Commons License
This work is licensed under a Creative Commons Attribution-NonCommercial-Share Alike 4.0 International License.
Humans and Nature in the Loop: Integrating occupants & natural conditioning into advanced controls for high performance buildings
Syracuse, NY
Post Occupancy Evaluation plus Measurements (POE+M) has revealed that thermal, visual, acoustic and even air quality standards derived through controlled experimentation alone does not ensure comfort or health in buildings. Introducing human input into environmental standards and into user centric controls is critically needed for a sustainable future. For over a decade, CMU’s Center for Building Performance & Diagnostics has been gathering POE+M data from over 1500 workstations around the world and testing the benefits on innovative environmental control systems. The separation of ambient and task conditioning, the provision of task controls, the introduction of occupant voting and bio-signal inputs into ambient and task set-points, offers major gains in comfort, task performance, energy savings, as well as health and wellness.