Conference Editor

Jianshun Zhang; Edward Bogucz; Cliff Davidson; Elizabeth Krietmeyer

Location

Syracuse, NY

Event Website

http://ibpc2018.org/

Start Date

26-9-2018 8:15 AM

End Date

26-9-2018 10:00 AM

Description

Post Occupancy Evaluation plus Measurements (POE+M) has revealed that thermal, visual, acoustic and even air quality standards derived through controlled experimentation alone does not ensure comfort or health in buildings. Introducing human input into environmental standards and into user centric controls is critically needed for a sustainable future. For over a decade, CMU’s Center for Building Performance & Diagnostics has been gathering POE+M data from over 1500 workstations around the world and testing the benefits on innovative environmental control systems. The separation of ambient and task conditioning, the provision of task controls, the introduction of occupant voting and bio-signal inputs into ambient and task set-points, offers major gains in comfort, task performance, energy savings, as well as health and wellness.

Comments

If you are experiencing accessibility issues with this item, please contact the Accessibility and Inclusion Librarian through lib-accessibility@syr.edu with your name, SU NetID, the SURFACE link, title of record, and author & and reason for request.

DOI

https://doi.org/10.14305/ibpc.2018.k03

Creative Commons License

Creative Commons Attribution-NonCommercial-ShareAlike 4.0 International License
This work is licensed under a Creative Commons Attribution-NonCommercial-Share Alike 4.0 International License.

COinS
 
Sep 26th, 8:15 AM Sep 26th, 10:00 AM

Humans and Nature in the Loop: Integrating occupants & natural conditioning into advanced controls for high performance buildings

Syracuse, NY

Post Occupancy Evaluation plus Measurements (POE+M) has revealed that thermal, visual, acoustic and even air quality standards derived through controlled experimentation alone does not ensure comfort or health in buildings. Introducing human input into environmental standards and into user centric controls is critically needed for a sustainable future. For over a decade, CMU’s Center for Building Performance & Diagnostics has been gathering POE+M data from over 1500 workstations around the world and testing the benefits on innovative environmental control systems. The separation of ambient and task conditioning, the provision of task controls, the introduction of occupant voting and bio-signal inputs into ambient and task set-points, offers major gains in comfort, task performance, energy savings, as well as health and wellness.

https://surface.syr.edu/ibpc/2018/keynotes/4

 

To view the content in your browser, please download Adobe Reader or, alternately,
you may Download the file to your hard drive.

NOTE: The latest versions of Adobe Reader do not support viewing PDF files within Firefox on Mac OS and if you are using a modern (Intel) Mac, there is no official plugin for viewing PDF files within the browser window.