Description
Radiant cooling power in the humid climates is inherently limited by condensation. This research investigates a type of radiant cooling methodology whereby the cold temperature source is convectively and conductively isolated from the environment with a membrane transparent to visible radiation to allow supply temperatures to be decreased for radiant cooling systems in humid climates. We conduct an FTIR analysis on three candidate membrane materials and fabricate a prototype experimental test panel that allows for thermal performance evaluation at different panel orientation and depths. Our study shows that for a 5 °C chilled panel temperature, the exterior membrane surface temperature reaches 26 °C in a 32 °C / 70% RH environment resulting in an effective panel temperature of 15.8 °C. Such a panel construction would avoid condensation in many humid environments and allow for radiant cooling without any latent load handling.
Recommended Citation
Teitelbaum, Eric; Rysanek, Adam; Pantelic, Jovan; Aviv, Dorit; Obelz, Simon; Buff, Alexander; Luo, Yongqiang; and Meggers, Forrest, "Condensation-free radiant cooling using infrared-transparent enclosures of chilled panels" (2018). International Building Physics Conference 2018. 1.
DOI
https://doi.org/10.14305/ibpc.2018.ie-6.01
Creative Commons License
This work is licensed under a Creative Commons Attribution-NonCommercial-Share Alike 4.0 International License.
Condensation-free radiant cooling using infrared-transparent enclosures of chilled panels
Syracuse, NY
Radiant cooling power in the humid climates is inherently limited by condensation. This research investigates a type of radiant cooling methodology whereby the cold temperature source is convectively and conductively isolated from the environment with a membrane transparent to visible radiation to allow supply temperatures to be decreased for radiant cooling systems in humid climates. We conduct an FTIR analysis on three candidate membrane materials and fabricate a prototype experimental test panel that allows for thermal performance evaluation at different panel orientation and depths. Our study shows that for a 5 °C chilled panel temperature, the exterior membrane surface temperature reaches 26 °C in a 32 °C / 70% RH environment resulting in an effective panel temperature of 15.8 °C. Such a panel construction would avoid condensation in many humid environments and allow for radiant cooling without any latent load handling.