Go to main content

As part of a larger project to develop prefabricated technologies for retrofitting building envelopes of Canadian homes, a small building was retrofitted and instrumented. This prefabricated retrofit method is intended to be applied directly over existing cladding. Two prototype retrofit wall systems were installed on the building; a nailbase panel, and a wood frame panel. The existing wall had an RSI value of 1.80 m2K/W (including film coefficients) and the resulting retrofitted walls reached values of 6.40 m2K/W and 5.72 m2K/W. With the addition of a new air barrier, blower door tests have shown a large reduction in infiltration from 7.62 ACH to 0.82 ACH at 50 Pa. This paper discusses the approach taken, the construction of the prefabricated panels, preliminary in-situ RSI measurements, and modelling of thermal bridging and energy savings for the pilot project.